  condor dc power supplies inc. 2311 statham pkwy oxnard, ca 93033 + 805-486-4565 ratings input: 100-240 vac, 5.5 a, 50/60 hz output: maximum continuous output power at 50c wi th external 26 cfm airflow = 200 w standard models: model output #1 1 i sc output #2 1 i sc output #3 i sc output #4 2 i sc gpm200a +5v 26a 5 25a +12v 8.0a 15a -12v 1.2a 2a 12v 4.0a 2a gpm200b +5v 26a 5 25a +12v 8.0a 15a -5v 1.2a 2a 12v 4.0a 2a gpm200d +5v 26a 5 25a +24v 5.0a 15a -12v 1.2a 2a 12v 4.0a 2a GPM200E +5v 26a 5 25a +24v 5.0a 15a -15v 1.2a 2a 15v 4.0a 2a gpm200f +5v 26a 5 25a +12v 8.0a 15a -12v 1.2a 2a 5v 4.0a 2a special models: (place code letters for desired ou tputs from table below; example = gpm200-baa) gpm200- ( ___ ) ( ___ ) ( ___ ) output #1 1 output #2 1 output #3 output #4 2 +5v 26a 5 b = +12v 8.0a a = -5v 1.2a q = -5v 2.4a a = 5v 4.0 a (for all c = +15v 8.0a b = -12v 1.2a r = -12v 2.4a b = 12v 4.0a models) d = +24v 5.0a c = -15v 1.2a s = -15v 2.4a c = 15v 4.0a d = 24v 2.0a notes: 1. the combined loads of outputs no. 1 and no. 2 mu st not exceed 32 a. 2. isolated output which may be referenced as a pos itive or negative voltage. 3. maximum operating relative humidity 96%, no cond ensation. 4. i sc = maximum output short circuit current. 5. minimum load current = 4a. safety declaration: condor dc power supplies, inc. declares under our sole responsibility that all models listed above are in conformity with the applicable requirements of en60950 following the provisions of the low volt age directive 73/23/eec. certification: all models are certified to be in compliance with the applicable requirements of ul 2601-1 1st ed, csa 22.2 no. 234 (level 3) (with additional tests to c22.2 no 601.1-m90 per t.i.l. ca-08), iec 601-1 (1988), en 60601-1: 1990 and vde 0750 t1 12.91. classification: (5.1) protection against electric shock = class i (in accordance with sub- (5.2) degree of protection against electric shock = signal output or intermed iate clause 5 of iec 601-1) (5.3) protection against har mful ingress of water = ordinary (no protection) (5.5) has not been evaluated for use in the presen ce of a flammable anaesthetic mixture with air, oxygen, or nitrous oxide. this evaluation is made on the end equipment by the oem. (5.6) mode of operation = continuous caution: when performing dielectric strength tests, catastro phic failure of the unit may result if a dielectric strength test voltage greater than 1800 vac is applied between primary and secondary circui ts. the components providing isolation from primary to secondary cannot be tested while installed in the power supply without overstressing basic (primary t o ground) insulation. all isolating components are individually 100% tested at 4800 vac prior to insta llation. 41-33222-0001 rev. e 1/29/02 page 1 of 2 gpm200 series installation instructions
isolation: the creepage distance between primary and ground is 4 mm minimum; between primary and secondary circuits is 8 mm minimum. secondary to ground cree page is not defined or controlled. the output comm on is bypassed to ground using a capacitor. the required creepage an d clearance distances from primary circuits to grou nd and secondary circuits must be maintained after installation to p reserve the intended safety. grounding: the protective earth (ground) terminal must be bond ed to protective earth in the host equipment. using the protective earth terminal on the supply for groundi ng the host equipment is not recommended. a separa te dedicated grounding point should be used. outputs: all output commons should be connected to protect ive earth in the end application. the output(s) ar e intended for protectively earthed signal output and intermed iate circuits only. the output(s) are not acceptab le for patient connection without additional isolation. all dc outputs are s elv under normal and single fault conditions. overvoltage protection: only output #1 is monitored for an overvoltage con dition. the trip-point for a 5 volt output is 5.6 to 6.8 volts. in some applications w here an overvoltage condition could result in a haz ard as defined in applicable safety standards, redundant or additiona l overvoltage protection may be required. consult factory for details. temperatures : the maximum operating temperatures of certain sa fety components, as defined in the applicable safet y standards, must not be exceeded after installation to preserve the intended safety. the output power, ambient air temperature and the availability, amount, direction and/or rest riction of airflow influence the temperatures of th ese components. overcurrent protection: the internal fuse is located in the phase lead only . en 60601-1 requires that both supply leads (phase and neutral) be protected again st overcurrent. complete overcurrent protection mu st be provided in the host equipment. fuse ratings must not exceed that specified for the internal fuse, must meet the requ irements of en 60601-1 and be acceptable for the country in which the host equipment is to be installed. warning! risk of fire! a blown internal fuse is an indication of catastrop hic failure of circuit component(s). repair must be performed by condor authorized personnel. refer to fuse marking on the supply for rating. warning! shock hazard! dangerous voltages are present on some components, printed wiring traces and heatsinks. attention, consult accompanying documents alternating current attention, dangerous voltages earth (ground) explanation of symbols c o n n e c t i o n s tb1 ac input j2 control connector tb2 dc outputs 1 line 1 power fail 1,2 output #1 (+) 2 neutral 2 output #1 (-) sense 3,4,5 common (retur n) 3 ground 3 output #1 (+) sense 6 output #2 (+) 4 no connection 7 output #3 (-) j2 mating connector = amp 64044x-4 where x = 0 to 4 8 output #4 (+) warning : do not exceed 15a per terminal on tb2 9 output #4 (-) condor dc power supplies inc. will not be liable fo r the safety, reliability or performance of these p ower supplies if a) any changes, modifications or repairs are carried out by other t han authorized agents of condor dc power supplies i nc., or b) the installation of the supply is not in accordance with these installation instructions and the applicable ul, csa, and/or ie c safety standards. 41-33222-0001 rev. e 1/29/02 page 2 of 2


▲Up To Search▲   

 
Price & Availability of GPM200E

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X